CBC Analyzer Calibrator accuratas, devestigabiles valores mensuras praebet ad hematologiam automatum analysres calibrandas, baseline accurate constituens parametris inclusis WBC, RBC, HGB, MCV et PLT.
Quid sunt Hematologia Imperium / Calibrators?
Hematologia controlla et calibratores speciales sunt, referentia- gradus biologicos materiae machinatum ad signa mensurationis laboratoriae conservandas.
- Calibratores notas continent concentrationes partium cellularum ad ponendos et componendos mensuras basilineas scalas hematologiae analystrorum.
- Imperia sunt exempla examinis stabilis adhibita in cottidiano vel trabea- ab- submoveo basium ad monitor perennem praecisionem ac reproducibilitatem systematis post calibrationem constituto.
Dissimiles generales reagentes operationales, quae cellam processus exercent in cyclis normalibus, calibratores et moderatores funguntur ut quantitatis referentiae signa quae requiruntur ad verificationem analyticam et qualitatis obsequium.
Munus in Hematologia Quality Control
Sustentationem analyticam accurate in plena sanguinis narratione probatio requirit congruentiam systematicam servandi.
Mensurae Traceability:Adsimilat impedimentum opticum et electrica canales cum rationibus internationalibus agnitis.
Post- sustentationem Recalibrationis:Systema accurationis reddit post adaptationes opticas, supplementum fluidum componentium, sensorem recalibrationem, vel instrumentum maioris operandi.
Reagent Lot Adjustments:Emendat baseline trabea optica, cum transitioning inter varias fabricandas sortes operandi reagentes.
Obsequium regulatory:Vexillum operandi modum servat requisita sub laboratoria accreditationum compagum.
Imperium gradus / Application
Ad qualitatem comprehensivam potestates consuetudines quae sequuntur calibrationem, hematologia systemata temperantia agunt per tres concentrationes physiologicas distinctas;
Low Level:Aestimat instrumentum sensitivum in cellula humilis enormiter comitum. Essentialia ad sanandas clinicae decisiones limina gravia anemia, leukopenia et thrombocytopenia.
Normalis Level:Comprobat mensurationem accurationem intra normas physiologicas pro exercitatione patientis protegendi.
Altus gradus:Expertus analysex detectoris responsionis ad concentrationes cellularum elevatarum in leukocytosi, erythrocytosi, vel thrombocytosi.
Calibrator imperium vs
|
Technical Parameter |
CBC Analyser Calibrator |
Hematologia Imperium (Low / Normal / High) |
|
Primarium munus |
Basesline instrumentum temperat et factors responsionem occidere |
Verifies mensurae subtilitatem et stabilitatem permanentem |
|
Frequency usus |
Periodica (Installatio, sustentatio, sors vices gerens) |
Quotidie, transfer - substructio, vel per experimentum batch |
|
scopum Pretio |
Una certa assignationis valorem per modulum cum limitibus angustis |
Valor definitus per regiones humili, normales, concentrationes; |
|
Munus Mathematica |
Mutationes calibratiis fastigio et intercipiendi ratio memoriae |
Insidiae puncta data in Levey- chartis Jennings ad summa deprehendere |
|
Metrologicum Standard |
Prima vel secundae materiae vexillum referat |
Secundarium qualitas materiae magna |
Compatible Hematology Analysers
Formatae cum componentibus biologicis stabiliuntur ut integrae notae specimen sanguinis aequant, integrationem sustinens per varia instrumenti suggesta;
3-Pars Ratio differentialis:Impedimentum- substructio calculis requirentibus calibrationem pro WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT.
5-Pars Ratio differentialis:Multi- angulus laser dispergat, cytometriam fluit, et suggesta chemica maculans per omnes sub- populos differentiales calibrationis requirens.
Pretio assignata / Morbi
Quaelibet sors contra methodos referentias convalescit et cum multus- certae Assay Value Sheet continens valores scopos et regiones acceptabiles praebent:
|
Parameter |
Abbreviation |
Typical Target Range |
assignata Unit |
|
Sanguis albis cellulis |
WBC |
6.5 - 8.5 |
x10^9/L |
|
Red Sanguis Cellae |
RBC |
4.00 - 5.00 |
x10^12/L |
|
Hemoglobin |
HGB |
120 - 150 |
g/L |
|
Medium Corpus Corpusculum |
MCV |
80.0 - 95.0 |
fl* |
|
Platelets |
PLT |
180 - 280 |
x10^9/L |
Product Specifications
|
Specification Item |
Singula |
|
Product Name |
CBC Analyser Calibrator |
|
Formula |
Confirmatur cellular suspensionis in conservativae medium |
|
Physica publica |
Liquid suspensionis |
|
Morbi assignata |
WBC, RBC, HGB, MCV, PLT, HCT |
|
Imple Volume |
2.0 mL / 3.0 mL per vial |
|
Traceability |
Ad internationalis referat signa |
|
Vestibulum Certification |
ISO 13485 |
|
Optiones packaging |
Multi- ampullae rhoncus magna cum sorte |
Repono & Stabilitas
Temperatus imperium conservat membranam cellulam integritatem et modulum stabilitatem in vita producta;
Repono Temperature inaperta:2 ad 8 gradus Celsi. Noli durare.
Shelf Vita:60 dies a fabricandis date conditis ad 2 ad 8 gradus Celsius.
Aperi- Stabilitatem vialem:7 dierum cum consignata reponuntur ad 2 ad 8 gradus Celsius statim post sampling.
Scelerisque Praesidium:Amet in temperatus- monitoria insularum sarcinarum monitoriis ad scelerisque stabilitatem in transitu tuenda.
Quality Assurance
Protocolla vestibulum sortem ponere-ad-multum constantiam et verificationem mensurae:
Metrologicum comprobatio:Omnis calibratio sors tribuitur valores utentes instrumentis referentibus verificatis contra signa internationalia.
Homogeneitas Testis:Random phialam sampling per cyclos productionis verificat intra- multum constantiam (Coefficiens variationis<= 1.0%).
Cras stabilitas:Verus- tempus et stabilitas accelerata probatio peracta est in omni massa productiva.
Documentation regulatory:Certificatorium Analysis et Salutis Data Sheet instructa unaquaque sorte partus.
FAQ
Q: Quoties analyser calibrari debet utens calibrator?
A: Recalibratio requiritur ad institutionem instrumenti initialis, post sustentationem praecaventivae consuetudinis, post reparationes majores, cum proventus qualitas diurnis constantem studium ostendunt, vel cum mutando ad novam sortem secundum protocolla laboratorium.
Q: Quid interest inter apertam- stabilitatem phialam ac fasciae vitae apertam?
A: Vita fasciae apertae refert ad periodum calibratoris bonas assignatas conservat cum repositae signatae ad 2 ad 8 gradus Celsius. Aperta stabilitas phialis - significat numerum dierum productum accurate post aperitionem manet, modo sub mundis conditionibus tractatur et ad 2 ad 8 gradus Celsius statim post usum rediit.
Q: Potestne hematologia controllata pro calibratore adhiberi?
A: No. Imperium monitor systematis praecisionis per ranges numerales, calibratores autem exactam referentiam praebent valores, quibus usus est analyser software ad accommodandum responsioni mathematicae curvae et factores calibrationis baselines.
Q: Quomodo calibrator ante sampling praeparetur?
A: Remove phialam ab 2 ad 8 graduum Celsius repositam et permitte aequilibrare ad locus temperatus (15 ad 30 gradus Celsius) pro 15 minutis. Permisceto lenem, inversionem integram antequam specimen specimen ad sampling specillum exhibens. Vitare commotionem ne cellam discidium vel bullae aeris.
Q: Quomodo temperatura in naviculas internationales servatur?
A: Ordines referti sunt in fasciculis scelerisque cum temperatus- materiae insulandi et sarcinarum frigidarum quae ad 2 ad 8 gradus Celsius per transitum aeris conservandum ordinantur.