Introduction
Lyser est propria solutio chemica adhibita ad tingendas cellulares (exempli gratia nuclei, cytoplasmi) in speciminibus sanguineis, ut instrumenta hematologia automata efficiant ad: genera cellularum sanguinis differentias (WBCs, RBCs, platelets), morphologicas abnormitates cognosce, parametros cellulares quantitare. Lyser pro instrumento hematologico Sysmex specialiter pro analysers seriei hematologiae Sysmex, inclusis diversis exemplaribus seriei 5-partis et 3-partium analystrorum.
Specifications
- Pro Sysmex 5-partium seriei:
XN series B1/B2/B3/B4
|
Code |
Descriptio |
Specification |
Tempus validitatis |
Temperature |
|
0307004 |
STAC- LYSER-SYSSLS |
1.5Lx2bottles/box |
24m |
2-35-gradus |
|
0307005 |
STAC-LYSER-SYSWNR |
4Lx2bottles/box |
24m |
2-35-gradus |
|
0307006 |
STAC-LYSER-SYSWDF |
4Lx2bottles/box |
24m |
2-35-gradus |
|
0307007 |
STAC-LYSER-SYSWPC |
1.5Lx2bottles/box |
24m |
2-35-gradus |
|
030700401 |
STAC- LYSER-SYSSLS |
500mlx3bottles/box |
24m |
2-35-gradus |
|
030700501 |
STAC-LYSER-SYSWNR |
5L/buxum |
24m |
2-35-gradus |
|
030700601 |
STAC-LYSER-SYSWDF |
5L/buxum |
24m |
2-35-gradus |
- Pro Sysmex 5-partium seriei:
XT-1800i/2000i/4000i
|
Code |
Descriptio |
Specification |
Tempus validitatis |
Temperature |
|
030403 |
STAC-LYSER-SYS-FBA |
5L/buxum |
24m |
2-35-gradus |
|
030003 |
STAC-LYSER-SYS-SLS |
5L/buxum |
24m |
2-35-gradus |
|
030501 |
STAC-LYSER-SYS-4DL |
5L/buxum |
24m |
2-35-gradus |
|
030502 |
STAC-LYSER-SYS-4DS |
42mlx3units/box |
24m |
2-35-gradus |
XE-2100/XE-5000
|
Code |
Descriptio |
Specification |
Tempus validitatis |
Temperature |
|
030403 |
STAC-LYSER-SYS-FBA |
5L/buxum |
24m |
2-35-gradus |
|
030003 |
STAC-LYSER-SYS-SLS |
5L/buxum |
24m |
2-35-gradus |
|
030501 |
STAC-LYSER-SYS-4DL |
5L/buxum |
24m |
2-35-gradus |
|
030502 |
STAC-LYSER-SYS-4DS |
42mlx3units/box |
24m |
2-35-gradus |
|
030504 |
STAC-LYSER-SYS-IM |
10L/arca |
24m |
2-35-gradus |
|
030505 |
STAC-LYSER-SYS-NR&Dye |
1L{1}}ml/buxum |
18m |
2-35-gradus |
XS-500i/XS800i/XS900i/XS1000i
|
Code |
Descriptio |
Specification |
Tempus validitatis |
Temperature |
|
030003 |
STAC-LYSER-SYS-SLS |
5L/buxum |
24m |
2-35-gradus |
|
030501 |
STAC-LYSER-SYS-4DL |
5L/buxum |
24m |
2-35-gradus |
|
030502 |
STAC-LYSER-SYS-4DS |
42ml x 3 unitates/box |
24m |
2-35-gradus |
- Pro Sysmex seriei 3-partium:
KX-21/KX-21N/poch-80i/poch-100i/XP-100/XP-300
|
Code |
Descriptio |
Specification |
Tempus validitatis |
Temperature |
|
030301 |
STAC-LYSER-SYS-WH |
500mlx 3bottles/box |
24m |
2-35-gradus |
K-1000/K-4500
|
Code |
Descriptio |
Specification |
Tempus validitatis |
Temperature |
|
030003 |
STAC-LYSER-SYS-SLS |
5L/buxum |
24m |
2-35-gradus |
|
030201 |
STAC-LYSER-SYS-3WP |
5L/buxum |
24m |
2-35-gradus |
Productumdetail
Applicatio:Lyser pro Sysmex instrumenti hematologiae Sysmex 5- seriei partis: XN-B1/XN-B2/XN-B3/XN-B4,XT-1800i/2000i/4000i,XE-2100/XE-5000,XS-500i/XS800i/XS900i. series:KX-21/KX-21N/poch-80i/poch-100i/XP-100/XP-300, K-1000/K-4500 hematologia analysris lineae.
- Origin:Shanghai, China
- Certification:CE, ISO 13485, CNAS L18717, MSDS .
- Pretium:Negotiable
- Partus date:Negotiable
- Stipare:export vexillum
- MOQ:1 set
- Pretium commodum:Cum reagentibus officinas originalis, magnum habet efficaciam sumptus.
FAQ
Q: Quid facit terrorem Lyser vacuam (Codex 103000)?
A: Solutio:
Repone exhaustum Lyser utrem.
Prima linea reagens: Sustentacionem > Reagent Primus > Lego Lyser.
Si persistit, utrem sensorem alignment (purgatum cum alcohol swab).
Q: Why does HGB show high blank (>0.2 g/dL)?
A: Causae:
contagione Lyser (eg, pulvis in COLLUM)
● tenui expired (verificare batch tutelam receptam alieni)
Crystallization in tibiis (common in humiditate<30%)
Figere:

Q: Shelf vita post foramen?
A: at Temp: maximam durationem
15-25 gradus : XC dies
>XXX gradus: XXX dies
Nota: "Scribe ostium date in utrem!
Hot Tags: lyser pro instrumento hematologico sysmex, Sina lyser pro instrumento hematologiae sysmex fabricatores, instructores